Morning, everybody. Think about the gear in a fall arrest system. The harness has a rating. The lanyard has a rating. The snap hook has a rating.

And the anchor? The anchor has somebody's opinion. "Looks stout." And then the whole system hangs on that opinion. That is what we are talking about today.

What the rule says

In Washington, an anchor for fall arrest has to hold five thousand pounds for each person attached. The other way to do it is for the anchor to be designed, installed and used as part of a complete system with a safety factor of at least two, under the supervision of a qualified person.

Washington adds one option. An anchor only has to hold three thousand pounds when it is used with either a self-retracting lifeline that limits free fall to two feet or less, or a shock-absorbing lanyard that holds the force on your body to nine hundred pounds or less. So "always five thousand" is not the whole rule, and "three thousand is fine" is not either. The lower number only comes with that specific gear.

The system has limits too

When a fall is stopped, the system must keep free fall to six feet at most, with no contact with a lower level. It must keep the force on your body to eighteen hundred pounds or less, and bring you to a stop within three and a half feet.

Where you tie off changes all of that. Tying off high, overhead if you can, keeps the fall short. Tying off down at your feet makes it longer. That is general good practice, and it follows from how the rule counts free fall.

Not an anchor, unless a qualified person says so

Federal says your harness is not to be attached to a guardrail system. Washington's rule for scaffolds says safe anchor points do not include piping, vents, electrical conduit, outrigger beams or counterweights. And your anchor has to be independent of whatever is holding up your platform, so that if the platform goes, you do not go with it.

So here is a list to say out loud. Sprinkler pipe, ductwork, conduit, a ladder rung, a light fixture, a rebar mat, a form, and "the truck." Nobody designed those to catch a person. If nobody can say why it holds, it does not count as an anchor.

If there is nothing good up there, the right answer is to stop and say so. That is not a failure. It means we find a real anchor or change how the work gets done.

One more

One person per vertical lifeline. No sharing a dropline.

Talk it over

  1. Point at the anchor you used most recently. Who says it holds?
  2. Is there anywhere on this job where the honest answer is "there is no good anchor here"?

Before you go

The anchor is the whole system. If you cannot say why it holds, it does not.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-880-40020(2)(b)(i) and (ii) (anchorage strength); WAC 296-880-40020(3) (free fall, arresting force, deceleration distance); WAC 296-880-40020(1)(l) (one employee per vertical lifeline); WAC 296-880-30030(9) (scaffold lifelines: fixed, safe point, independent of the scaffold, and the note on what is not a safe anchorage). Federal: 29 CFR 1926.502(d)(15) (anchorage strength; independent of platform anchorages), (d)(16), (d)(23) (not attached to guardrail systems). The list of things that are not anchors beyond the scaffold note is common sense, not a quotation of the rule.