R Safety Hub R Safety Hub Your prescription for a safer workplace

Extension Cords, GFCIs and Power Lines

Lines in italics are for the reader, not the crew. If you can, hold up one of the crew's extension cords while you talk. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Today is about electricity. Not the electrician's work. Ours. The cords we drag around, the outlets we plug into, and the wires over our heads.

Electricity doesn't give warnings. A cord doesn't smoke before it bites. So we check things before they bite.

GFCIs

A GFCI is the device that trips when current goes somewhere it shouldn't, like through you. You know it by the test and reset buttons.

Washington's rule says every regular one-twenty volt outlet we use on a construction site has to be GFCI protected, unless it's part of the building's permanent wiring. Temporary power and spider boxes included. There's a narrow exception for some small portable generators, so if you're not sure about ours, ask. The only other way the company can do it is a written program where a competent person tests cords and checks them every day. One way or the other, we're covered. Never neither.

If a GFCI trips, it's telling you something. Don't tape the button. Don't go find an outlet without one. Find out why.

Check the cord every day

Before you use a cord, look at it. End to end. Run it through your hands if you can.

The rule says no worn or frayed cords. Look for cuts or nicks in the outer jacket, inner wires showing, a crushed spot, a missing or bent ground pin, a cracked plug. If you find one, tag it out and get it off the job. Don't just put it back on the truck for the next person.

Note for the reader: hold up the cord now and point at the ground pin and the jacket.

Extension cords for power tools have to be three-wire and rated for hard or extra-hard use. That skinny orange one from the garage probably isn't.

And no homemade splices. The rule says cords are used in one continuous length. Electrical tape on a cut cord is not a repair. It's a bandage on a snakebite.

Treat cords right

No stapling cords, hanging them on nails, or tying them up with wire. That chews through the jacket. Don't lower a tool by its cord. And keep cords out of walkways where somebody can trip.

When you plug in or unplug, your hands have to be dry. If the connection is wet, don't grab it bare-handed.

If a breaker trips, don't just keep slapping it back on. The rule says find out it's safe first. Resetting it again and again is against the rule.

Look up

Every overhead wire is live until the power company says otherwise and it's been visibly grounded. You can't tell by looking. Neither can anybody else.

If you're not a trained electrical worker, you, and anything you're holding, stay at least ten feet from overhead lines. That counts the ladder, the pipe, the long piece of siding, the gutter and the paint pole. More distance for higher voltage. Equipment that raises up, like a boom or a dump bed, keeps ten feet too.

Aluminum ladders and power lines are a bad combination. Near anything energized, the rule wants ladders with nonconductive side rails. And take off rings and metal watch bands around exposed electrical parts.

Talk it over

  1. Show of hands. Who checked their cord today before plugging in?
  2. Where are the overhead lines on this job, and what's the closest we'll get to them?

Before you go

GFCI on every temporary outlet, check the cord, no tape repairs, dry hands, and ten feet from the lines.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-155-447(2)(a) (GFCIs on 120-volt, 15- and 20-amp construction-site outlets not part of permanent wiring, or an assured equipment grounding conductor program with daily visual inspection); -428(5) (no worn or frayed cords; no staples, nails or wire); -428(7) (not raised or lowered by cord); -449(1)(b)(ii)(J) (three-wire, hard or extra-hard usage); -449(7)(b)(iii) (continuous lengths without splice; hard-service No. 12 or larger may be properly spliced); -428(2)(b) (cords not a tripping hazard); -428(9) (dry hands; wet connections only with insulating protection); -428(11) (no repeated resetting); -428(1)(m) (overhead wire energized until owner says otherwise and visibly grounded); -428(18), (20) (ten feet at 50 kV or below for unqualified persons and conductive objects; raised equipment); -428(24), (25) (nonconductive ladder side rails; conductive jewelry). Federal: 29 CFR 1926.404(b)(1); 1926.405(g)(2)(iii). How a GFCI works, the test and reset buttons, the list of cord defects beyond the rule's own examples, "electrical tape is not a repair" and "aluminum ladders and power lines" are plain explanations or common practice, not quoted rule text. The tape line agrees with the rule's ban on splices.