R Safety Hub R Safety Hub Your prescription for a safer workplace

Extension Ladders: Setup and Inspection

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Nobody plans their ladder. We lean it, we look at it, and we go. And every one of these rules sounds fussy right up until the day it is not.

So here is a thirty-second setup check you can do without a tape measure. Walk up to the ladder, stand with your toes at the feet of it, and stick both arms straight out in front of you, like a very friendly zombie. If your palms land flat on a rung, the angle is about right. If you have to reach, it is too flat. If you are pushing, it is too steep. It is a common field check, not something in the code, so the code's own rule comes next.

What the rule says

The ladder is set at the proper angle when the distance from the top support to the foot is approximately one-quarter of the working length. Twelve feet of working length, about three feet out at the bottom.

If you are using it to step onto an upper level, the side rails must go at least three feet above the landing, if the ladder is long enough. If it is not, the ladder is secured at the top to a rigid support that will not give, and there has to be something to hold onto.

If the ladder is where work or traffic could knock it, either secure it or barricade the area. "I told everybody it's there" is not one of the two choices. If it is in front of a door that opens toward it, block the door open, lock it, or guard it.

Set it on a firm, level surface, or secure it. Never on boxes or barrels to get a little more height.

Climbing

Use at least one hand on the ladder going up and going down. Face the ladder. Keep the rungs free of oil and grease. And do not carry anything that could throw off your balance. Three points of contact is good practice, but the rule itself says at least one hand.

Inspection

The person using the ladder looks it over before first use each shift, and again if something happens to it, like a tip-over or a hit. Look for bent, broken or split rails, bent, broken or missing rungs, loose bolts and rivets, frayed rope, moving parts that bind, worn feet, and corrosion.

A ladder with damage gets marked or tagged "do not use" and removed from service. Not leaned against the fence for later.

Electricity

Where a ladder could touch uninsulated, energized lines or equipment, use a ladder with non-conductive side rails. Metal ladders and power lines are a bad combination.

Talk it over

  1. Go set the ladder you will use next and do the arms-out check. Was it right?
  2. Is anything on this site parked where a ladder would be in a traffic lane or a door swing?

Before you go

One out for every four up, three feet past the landing, secured or barricaded, and a hand on it the whole way.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-876-40020(1) (angle); 296-876-40030(1) and (2) (three feet above landing); 296-876-40010 (traffic and doors); 296-876-40015 (support); 296-876-40025 (climbing, one hand, facing, slippery rungs, loads); 296-876-30005(1), (3) and (4) (condition, inspection, removal from service); 296-876-40035 (electrical). Federal: 29 CFR 1926.1053(b)(1) and (b)(5)(i). WAC 296-876-20005 points to ANSI A14 ladder standards; that pointer is in the regulation, and this talk does not quote the ANSI standards. The arms-out check is a common field method, not part of the rule.