R Safety Hub R Safety Hub Your prescription for a safer workplace

Fall Protection Basics: When Is It Required?

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Quick quiz, no wrong answers allowed to get you in trouble: at what height does fall protection start in Washington?

If you said six feet, you are in very good company. Most people do. Six feet is the federal number. In Washington, it is four. So if your gut says six, it is two feet off, and two feet is plenty to matter.

What the rule says

In Washington, if you are on a walking or working surface with an unprotected side or edge four feet or more above the ground or a lower level, you must be protected. Depending on the work, that can be a standard guardrail, a fall restraint system, a fall arrest system, a safety net, a catch platform, or a warning line.

A few jobs have a higher number, and they are narrow. Six feet for roofing work on a low-pitched roof and for constructing a leading edge. Ten feet for erecting or placing structural members, with a catch: if that work is done from a floor, deck or roof, it is back to four. Ten feet also applies to excavation and trenching work, with some exceptions. Everything else is four.

Some things count at any height

Holes you could trip into or step through must be covered or guarded. Open sides above dangerous equipment must be guarded. And impalement hazards, like exposed rebar, must be protected no matter how high up you are.

Four feet and ten feet are two different numbers

Four feet is when fall protection starts. Ten feet is when the employer needs a written fall protection work plan for that area, and the crew has to be trained on it before going in. Being under ten feet does not mean you are unprotected. It just means no binder is required. If a guardrail takes the fall hazard away completely, the plan is not required.

Steep roofs

On a roof steeper than four in twelve, warning lines and safety monitors are not allowed. You are on restraint, arrest, or a positioning device. A buddy watching you is not fall protection on a steep roof.

What a guardrail actually is

A standard guardrail has a top rail, a middle rail and posts. The top rail is between thirty-nine and forty-five inches high, and the whole thing has to take two hundred pounds pushed outward or downward near the top edge. So a single two-by-four nailed across two studs is not automatically a guardrail. Nice try, though.

Restraint, which keeps you from reaching the edge, is better than arrest, which catches you after you have fallen, whenever the job allows. Not falling beats being caught.

Talk it over

  1. Before today, what number was in your head, four or six?
  2. Where on this job do we work between four and six feet up, where somebody might think they are fine?

Before you go

Four feet in Washington. Ten feet adds the written plan. Rebar and holes get guarded at any height.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-880-20005 (four feet; steep roofs, subsection (6)); WAC 296-880-30005(1) and (2) (six and ten foot construction triggers, with exceptions); WAC 296-880-10010 (regardless of height); WAC 296-880-10020 (written plan at ten feet or more); WAC 296-880-40005 (guardrails). Federal: 29 CFR 1926.501(b)(1) (six feet). Washington is stricter than federal here, and Washington applies in Washington.