Morning, everybody. Today is about the ladder nobody carries. The fixed ladder. The one bolted to a building, a tank or a piece of equipment.
Because it is bolted on, people treat it like a staircase. But it may have been out in the rain for twenty years, and the only person checking it this morning is you.
Check it before you climb
Washington's rule says a trained ladder user looks it over before their first climb of the shift, and again if something happens during the shift. Look for broken or missing rungs, bent or split rails, rust that has eaten into the metal, and bolts or welds that are missing or loose. Look for sharp edges and burrs that could cut your hands.
If the ladder got hit by a truck or a machine, went through a fire or high heat, or has been around chemicals that eat metal, that calls for the company's competent person to look it over before anyone climbs.
If it is damaged
A damaged fixed ladder comes out of service right away. You can't carry it back to the truck, so mark it as defective, tag it "do not use," or block it so nobody can climb, like a sheet of plywood over several rungs. Then tell your supervisor.
A repair has to put the ladder back the way it was designed. Somebody always says, "I'll just skip that rung." No. The whole ladder is out.
Climbing it
Face the ladder going up and coming down. At least one hand on it. Keep the rungs free of oil, grease and anything slick. Don't carry anything that could throw off your balance. A tool pouch, or a bag pulled up on a line after you get there, is good practice.
Don't overload it, and use it only for what it was built for. And the company has to make sure ladder users are trained by a competent person, and retrained when needed.
The tall ones
When the top of a fixed ladder is more than twenty-four feet up, the rules call for a cage, a well, or a ladder safety system, like a cable or rail you clip into. On a single climb of twenty-four feet or more, a cage alone is not enough. It needs a ladder safety device, or sections with a cage or well, no longer than fifty feet, each offset from the next, with landings between. Cages are being phased out as fall protection. So if the ladder has a safety system, use it, the way you were trained. If nobody has shown you how, ask before you climb. That part is good sense.
At the top
On most fixed ladders the rails or grab bars stick up above the landing so you have something to hold as you step off. Use them. Where a ladder comes up through a floor or roof opening, the opening gets a guardrail with toeboards, and a gate or an offset, so nobody walks straight into the hole. If that gate is missing or propped open, say something.
Talk it over
- Where on this job is there a fixed ladder, and when did somebody last really look at it?
- If you found a cracked rung halfway up, what would you do right then?
Before you go
Look before you climb, face it, one hand on it, nothing in your hands, and if it's damaged, block it and tell someone.
Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.
Get started
Reference (not read aloud). Washington: WAC 296-876-099 (fixed ladder: permanently attached to a structure, building or equipment; cage; carrier); 296-876-100 (scope; ladder safety system harness and rope or cable grab rules are in chapter 296-880); 296-876-15005 (training by a competent person); 296-876-70010(1), (2)(a), (b), (3) and notes, (4), (6), (8) (keep in safe condition; trained user inspects before initial use each shift and as necessary; impact, fall, struck-by or corrosive exposure calls for a competent person inspection; structural damage removed from service immediately; damage examples: broken or missing rungs, cleats or steps, broken or split rails, corroded components, bolts and welds missing or not secure; removed from service means marked defective, tagged "do not use," or blocked, for example plywood over several rungs; repairs restore original design; free of splinters, sharp edges, burrs and projections; rungs parallel, level and uniformly spaced); 296-876-80005 (maximum intended load, manufacturer's rated capacity); 296-876-80010(1) to (5) (one hand, face the ladder, free of oil and grease, no load that could cause loss of balance, used only for designed purpose); 296-876-60065 and note (cage, well or ladder safety system where climb under 24 feet but top over 24 feet; single climb of 24 feet or more: ladder safety device, or caged sections not over 50 feet, offset, landings at 50 feet; construction exemption: self-retracting lifeline with landings at 150 feet; note: cages being phased out, new fixed ladders constructed after October 1, 2020 must have ladder safety systems, existing ones by October 1, 2040); 296-876-60050(1) (side rails of through or side-step ladders extend 42 inches above the access level); 296-880-20005(3)(d) (ladderways guarded by guardrail and toeboards, passage with a swinging gate or offset). Which section applies: 296-876-60050 and -60065 sit under 296-876-600, fixed ladders installed before December 1, 2006; ladders installed on or after that date go by 296-876-50010, which points to ANSI A14.3 (not described here); the federal cage and 42-inch rules, 1926.1053(a)(18), (19), (24), carry no install-date split. That is why the talk says "the rules call for." Competent person triggers: 296-876-70010(2)(a) points to Table 1 in 296-876-30005 (impact, excessive heat such as a fire), and (2)(b) names tip-over, fall, struck-by and corrosive use. Training: 296-876-15005(2). Federal: 29 CFR 1926.1053(a)(18), (19) (cages, wells, ladder safety devices or self-retracting lifelines at 24 feet), (a)(24) (42-inch rail extension), (b)(15) (competent person inspection periodically and after any occurrence), (b)(17) (fixed ladders with structural defects withdrawn from service until repaired), (b)(18) (repairs), (b)(20), (21), (22) (face the ladder, one hand, no load causing loss of balance). The pre-shift user check is a Washington rule; no matching federal sentence was found in 1926.1053. "The only person checking it this morning is you," "skip that rung," wire and duct tape as an example of what is not a repair, the tool pouch or bag on a line, and "if it has a safety system, use it; ask before you climb" are good practice or plain explanation, not rule text. WAC 296-876-50010 points to ANSI A14.3 for design; this talk does not describe it.