R Safety Hub R Safety Hub Your prescription for a safer workplace

Guardrails

Lines in italics are for the reader, not the crew. If there is a guardrail in sight, stand where the crew can see it. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Today is about the guardrail. The two-by-fours on the edge of the deck. The cable around the floor. The pipe rail at the stair opening.

A guardrail is the quietest fall protection on the job. Nobody has to put it on. Nobody has to clip in. It protects everybody who walks by, all day, without being asked. Which is exactly why it is a problem when one goes missing.

Where it comes in

In Washington, an open side or edge four feet or more above the ground or the level below needs fall protection. A standard guardrail is one of the ways the rule allows.

What a standard guardrail is

The rule spells it out.

It has a top rail, a mid rail and posts.

The top of the top rail sits thirty-nine to forty-five inches above the floor. The mid rail goes halfway between the top rail and the floor.

It has to be strong. The finished rail has to take at least two hundred pounds, pushing out or pushing down, anywhere along the top edge.

For a wood rail, the rule gives sizes. Posts at least two-by-four, no more than eight feet apart. Top rail at least two-by-four. Mid rail at least one-by-six.

For wire rope, the cable is pulled tight, it stays between thirty-nine and forty-five inches high the whole way, and the top cable is flagged with something bright at least every six feet.

So think about caution tape for a second. Tape will not hold two hundred pounds. Tape is a warning. It is not a guardrail.

Toeboards

Where people can pass underneath, or there is machinery or equipment below, the guardrail gets a toeboard. The rule says at least three and a half inches tall, fastened down, with no more than a quarter inch gap at the bottom. The toeboard is there for the people below. It keeps a kicked tool on your level.

Taking one down

Sometimes a rail has to come down to land material. The rule has a plan for that.

When a guardrail must be taken down for a specific task, somebody attends that spot the whole time, until the rail is back. That person has one job, which is warning people about the edge. And that person is protected by fall arrest or fall restraint.

So "I'll put it back after lunch" is not in the rule.

Working above the rail

A guardrail protects you when you are standing on the floor. Set a stepladder next to it and climb, and now you are above it. The rule covers that. If people work from ladders or platforms above the rail's protection, the rail gets raised, or another kind of fall protection gets used. Same idea on stilts. The top rail goes up by the height of the stilts.

Good practice

This part is good practice, not the rule's words.

Don't sit on a guardrail, and don't climb it.

If a rail is loose, sagging or missing, fix it if that is your job. If it is not your job, report it right then. Don't assume the last ten people who walked by already did.

And if you took it down, you put it back.

Talk it over

  1. Where on this job do rails come down for loading, and who watches the opening while they are down?
  2. Is there a rail on this site that anybody here does not trust? Go look at it right after this talk.

Before you go

Top rail, mid rail, two hundred pounds. And if a rail comes down, somebody stands watch until it is back up.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-880-20005(1) and (1)(a) (unprotected side or edge four feet or more; standard guardrail is one listed system; toeboard where persons can pass, there is moving machinery, or equipment below), (1)(a)(i) (stilts), (1)(a)(ii) (working from platforms or ladders above the guardrail), (1)(a)(iii) (temporary removal: constantly attended, warning as the only duty, attendant in fall arrest or restraint); 296-880-40005(1) (top rail, intermediate rail, posts; 39 to 45 inches; intermediate rail halfway), (2)(a) (wood sizes, posts not over eight feet), (2)(d) (wire rope: taut, 39 to 45 inches at all points, top rail flagged at not more than six-foot intervals), (2)(e) (200 pounds within two inches of the top edge, outward or downward), (3)(a) (toeboard three and one-half inches, not more than one-quarter inch clearance). Pipe and structural steel sizes, and the other fall protection systems on the list, were left out. Federal: 29 CFR 1926.502(b)(1) (42 inches plus or minus 3), (b)(2)(i), (b)(3) (200 pounds), (b)(9) (wire rope flagged every 6 feet). "Tape will not hold two hundred pounds" is our plain reasoning from the strength line; the rule's text does not mention tape. The good-practice section is not rule text.