Morning, everybody. Today is about the homemade ladder built from two-by lumber and cleats, the kind going into a footing or up to a deck before the stairs are in.
A job-made ladder is a real ladder. It just didn't come from a store. Today is how it gets built and checked. Next time is how we set it up and use it.
What it's for
In the rule, a job-made ladder is one made to fit a certain job, for temporary use. It's there until that phase of the work is done, or until the permanent stairs or fixed ladder are ready. It isn't meant to stay after that.
How it's built
The rule says a job-made wooden ladder built since 2006 has to meet the design standard written for job-made wooden ladders. We don't go into that standard here. If you're the one building it, get the building details from your supervisor before you start cutting. Not from a guess.
What all of us can check
The cleats are parallel, level and evenly spaced. Under the federal rule, that's ten to fourteen inches apart, center to center. Each cleat gives you at least eleven and a half inches of clear width to stand on.
The joints between the cleats and the rails are tight.
No cleats bent, cracked, broken or missing.
No side rails bent, broken or split.
No nails sticking out, and no splinters or edges that can puncture, cut or snag.
Nothing else faulty or defective. The rule lists more; these are the common ones.
No paint covering the wood. A wood ladder can't be coated over, except the smallest amount needed for a label or warning, on one face of one rail. Paint hides cracks.
Checking it
Look it over before you use it each shift, and again any time something happens to it, like it gets knocked over or hit. After that kind of damage, a competent person checks it before it's used again. That's someone who knows ladders and the ladder rules, and who has the authority to fix the problem.
If it has structural damage or any other dangerous defect, it gets marked as defective or tagged "do not use," and it comes out of service.
A split or broken side rail does not get patched. The rule says no repairs to a defective side rail. Any other repair has to bring the ladder back to how it was designed before it's used again.
And don't load-test it. No bouncing on it or hanging weight on it to prove it's strong. The rule says load and impact tests can weaken the lumber and the fasteners, and hide damage until it fails under somebody.
Talk it over
- Do we have a homemade ladder on this job that should be gone because the stairs are in?
- If you found a cracked rail on one, what would you do with it?
Before you go
Built to the standard, cleats even and wide enough, rails sound, no paint, checked each shift and after any knock, and never patched or bounced on.