R Safety Hub R Safety Hub Your prescription for a safer workplace

Keeping Exits Open During Remodels

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Today is about the way out. Especially on remodels, tenant improvements and any job inside a building where people are still working or living.

On a remodel, we're the ones who block the hallway with drywall carts, prop the fire door open with a bucket, and tape plastic across the stairwell. And then there's a fire alarm, and everybody in that building needs to get out the way we just blocked.

What the rule says

In Washington, people can't keep working in an existing building during construction or repair unless all the exits and the existing fire protection are kept working, or other fire protection is provided that's just as safe. That duty is on the employer, but our materials and our mess are usually what's in the way.

Exit routes stay free of anything in the way, all the time, so everybody can get out in an emergency. Not "mostly clear." Clear.

Nobody should have to head into a dead end, or through a room that can be locked, to get out.

Exit doors have to open from the inside without a key, a tool or special know-how. So no screwing a door shut to keep dust in, and no padlock on the inside. And no device or alarm on an exit door that could keep it from opening if the device fails.

Flammable or explosive materials we bring in for the work can't add danger or block the way out. Our gas cans, solvents and adhesives don't get parked in the exit path, and nobody should have to head toward them to get out.

The safety stuff

Sprinklers, alarms, fire doors and exit lighting have to stay in working order. That means we don't bag a smoke detector and forget it, cover a sprinkler head with plastic, or wedge a fire door open and walk away. If the work truly needs one of those changed for a while, that's a supervisor's call, not ours.

Exit signs can't be covered or hidden, and nothing gets taped on an exit door that hides it. Our plastic sheeting goes around them, not over them. And a door that looks like an exit but isn't gets marked "not an exit."

New buildings

On a new building, the rule says there have to be enough working exit routes before employees move in to work there. Good practice for us: before the shift, know two ways out of where you're working.

Good practice

Not rule text. Walk your exit path at the start of the day. If our stuff is in it, move it. If somebody else's stuff is in it, tell your supervisor.

Talk it over

  1. On this job, what have we put in an exit path this week? Be honest.
  2. Is there a fire door, sprinkler or exit sign we've covered, blocked or propped?

Before you go

Exits clear, doors that open from inside, fire doors closed, sprinklers and signs uncovered, and know two ways out.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-800-31065(1) (enough compliant exit routes before employees occupy a workplace under new construction), (2) (employees do not occupy an existing workplace unless all exits and existing fire protection are maintained, or alternate fire protection gives an equivalent level of safety), (3) (flammable or explosive construction and repair materials do not expose employees to added hazards or prevent emergency escape); 296-800-31025(1), (2) (exit routes always free of obstructions; no travel to a dead end or through a lockable room); 296-800-31030 (exit doors open from inside without keys, tools or special knowledge; outside-only locking devices allowed); 296-800-31045(1), (2) (exit routes maintained to minimize danger; free of explosive or highly flammable furnishings and decorations); 296-800-31050(3), (6), (7) (passages that might be mistaken for an exit marked "not an exit" or with their use; exit signs not obstructed or concealed; exit doors free of signs that obscure them); 296-800-31060 (sprinklers, alarms, fire doors and exit lighting kept in proper working order); 296-800-100 (core rules affect all employers). Federal: 29 CFR 1926.34(a) to (c) (free and unobstructed egress at all times when occupied; exits marked; means of egress maintained free of obstructions). "Our materials and our mess are usually what's in the way," the examples (carts, buckets, plastic, bagged detectors, screwed-shut doors, padlocks), "a supervisor's call," and "know two ways out" are plain explanation or good practice, labelled where spoken as such. Also 296-800-31030 (no device or alarm that could restrict emergency use if it fails); 296-800-31045(3) (no required travel toward high hazard materials unless protected by partitions or barriers); "nobody should have to head toward them" applies (3) to our flammables, our reading.