R Safety Hub R Safety Hub Your prescription for a safer workplace

Ladder Jack Scaffolds

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Today is ladder jacks. Two ladders, two brackets and a plank.

It is the fastest scaffold on the job. It goes up in ten minutes. That is the good news, and it is also the bad news, because anything that goes up that fast gets treated like it does not count.

It counts. Washington's scaffold rule has a section just for ladder jacks, and the general scaffold rules apply too.

The ladders

The ladders that hold a ladder jack have to be Type One or Type One A. Type One is rated for two hundred fifty pounds. Type One A is rated for three hundred. A ladder rated heavier than Type One also meets the rule. A ladder rated lighter does not.

So read the label on the side rail before you hang a jack on it.

The ladders have to be placed, fastened or fitted with something so they cannot slip.

And no job-made ladders. A ladder somebody built on site does not hold a ladder jack.

The jacks

The jack has to be designed and built to rest one of two ways. On the side rails and the rungs together. Or on the rungs only.

If it rests on the rungs only, it has to bear on at least ten inches of each rung.

The platform

The platform goes no higher than twenty feet.

It is at least twelve inches wide.

Platforms are not bridged together. One platform does not get tied into the next one to make a longer run.

Load it the way the maker's instructions say, or the way a qualified person designed it. And never past the maximum intended load or the rated load, whichever is less. Two people, their tools and a stack of material add up quicker than you think.

And nothing goes on the platform to make you taller. No boxes, no barrels, no buckets.

Fall protection

The scaffold fall protection rule says anyone on a scaffold who could fall ten feet or more to a lower level has to be protected.

On most scaffolds that means guardrails or a personal fall arrest system. For a ladder jack scaffold, the rule names one. A personal fall arrest system. Harness, lanyard, and an anchor.

The line that names the harness for ladder jacks does not give a height of its own. So we take the safe reading. On a ladder jack, wear the harness and tie off.

The rule says what the lanyard connects to. A vertical lifeline, a horizontal lifeline, or a proper structural part of the scaffold.

A vertical lifeline is fastened to a fixed, safe anchor point. It is independent of the scaffold. And it is protected from sharp edges and rubbing.

The rule's note says what a safe anchor point is not. Not a standpipe, a vent or any other piping. Not electrical conduit. Not an outrigger beam. Not a counterweight. A structural member of the building can be one.

There is one more piece. If the front edge of the platform is more than fourteen inches from the wall you are working on, the rule calls for a guardrail along that front edge, or a personal fall arrest system. For plastering and lathing, that distance is eighteen inches. On a ladder jack, the rule has already named the harness, so a front rail does not take its place.

Here is some good practice, not the rule's words. Work out where you will tie off before the plank goes up. It is a lot harder to figure out from the plank.

Who sets it up, and who checks it

A competent person, someone the company picks, oversees putting it up and taking it down. They check it before every shift, and after anything that could affect it. Damaged parts get fixed or come out of service. And the ladders are still ladders, so the ladder rules still apply.

Talk it over

  1. What does the label on our ladders say? Type One, Type One A, or something else?
  2. On this job, ten feet up on a ladder jack, where would you tie off?

Before you go

Rated ladders that cannot slip. A platform no higher than twenty feet. And a harness that is tied off.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-874-40026(1) (platform not higher than 20 feet), (2), (3) (jacks rest on side rails and rungs together or on rungs only; rungs-only bearing area at least 10 inches on each rung), (4)(a) and note (ladders Type I, 250 pound rated capacity, or Type IA, 300 pound; a ladder with a greater duty rating than Type I satisfies it), (4)(b) (placed, fastened or equipped to prevent slipping), (5) (no job-made ladders), (6) (platforms not bridged together); the section's history line shows it was last amended by WSR 26-15-109, filed 7/21/26, effective 8/21/26. WAC 296-874-20010 Table 1 (ladder jack platform minimum 12 inches); 296-874-20038 (loading); 296-874-20042(1) (no makeshift devices such as boxes and barrels); 296-874-20004 (competent person; trained and experienced employees); 296-874-20034 (inspection before each work shift and after anything that could affect structural integrity); 296-874-20036 (damaged or weakened components repaired, replaced, braced or removed from service). WAC 296-880-30030(1) (scaffolds: protection from falling ten feet or more), (2) (lanyard attached to a vertical lifeline, horizontal lifeline or appropriate structural member of the scaffold), (5) (front edge more than 14 inches from the work face, 18 inches for plastering and lathing), (6)(a)(iv) (ladder jack scaffold: personal fall arrest system), (9)(a) and its note (vertical lifelines; safe points of anchorage include structural members of buildings but not standpipes, vents or other piping systems, electrical conduit, outrigger beams or counterweights). The talk gives both facts and then says, as our safe reading and not as rule text, to wear the harness and tie off on a ladder jack; "a front rail does not take its place" is the same reading. No L&I interpretation was looked up. Ladders: chapter 296-876 WAC. Federal: 29 CFR 1926.452(k)(1) to (5). The federal ladder jack paragraph read today says the ladders meet the federal ladder subpart and are not job-made; it does not carry the Type I or Type IA line. The federal scaffold fall protection section (1926.451(g)) was not read today. "Buckets" is our plain addition to the rule's "boxes and barrels." "Harness, lanyard, and an anchor" is plain explanation. The tie-off planning lines and the first talk-it-over answer are good practice, not rule text. No maker's manual was read. The scaffold rule's access, planking and platform-length sections were left out for length.