Morning, everybody. Between your harness and your anchor there is a lanyard and a couple of hooks. That is the part people improvise with. Clip it to this, loop it around that, two of us on one line.

Here is the rule of thumb for today. If the connection feels clever, it is probably on the prohibited list. Cleverness is great for crossword puzzles. Not so great at the end of a lanyard.

What the rule says

Snap hooks have to be the locking kind. A locking snap hook takes two separate moves to open, one to release the keeper and one to open the gate, and the gate closes by itself when you let go.

Unless the hook is specifically designed for it, a snap hook must not be connected: directly to webbing, rope or wire rope; to another snap hook; to a D-ring that already has another snap hook or connector on it; to a horizontal lifeline; or to anything shaped or sized so that it could press the keeper open and let the hook slip free. That last one is called roll-out, and it happens quietly.

Strength

Lanyards and vertical lifelines have a minimum breaking strength of five thousand pounds. The exception is a self-retracting lifeline or lanyard that limits free fall to two feet or less, which is three thousand pounds. D-rings and snap hooks have to be proof-tested to thirty-six hundred pounds without cracking, breaking or taking a permanent bend.

Only one person per vertical lifeline. Lines and lanyards must be protected from being cut or rubbed through, so think sharp edges, hot work and roof corners.

Horizontal lifelines are engineering, not rigging. They must be designed, installed and used under a qualified person, with a safety factor of at least two. Nobody strings one up on a hunch.

What the whole system has to do

When it catches you, free fall is limited to six feet, with no contact with a lower level. The force on your body is limited to eighteen hundred pounds, and you have to stop within three and a half feet. The only way to allow more than six feet of free fall is if the manufacturer designed and tested the system for it. That is a spec sheet, not a judgment call on a roof.

About retractable lifelines

A self-retracting lifeline pays out and locks, a bit like a seatbelt, and it shortens your free fall a lot. But there is no separate, shorter stopping number for them in the rule. The same six feet, eighteen hundred pounds and three and a half feet apply. And only a retractable that actually limits free fall to two feet or less gets the lower strength figure. Not every retractable does. So read the label on the one in your hand.

Talk it over

  1. Look at your snap hook. Does it take two moves to open, or one?
  2. Has anyone here ever hooked back onto their own lanyard to choke it around a beam?

Before you go

Locking hooks, one hook per D-ring, one person per line, and nothing clipped to webbing.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-880-40020(1)(c) through (m) and (3). Locking snap hook defined in WAC 296-880-095. Federal: 29 CFR 1926.502(d)(5), (6), (8), (9), (11), (12), (16). Note: a note under WAC 296-880-40020(3) points to ANSI Z359.1 for shock absorbers; that pointer is in the regulation. This talk does not quote or explain the ANSI standard itself.