Lighting on the Job

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Today is about light. Being able to see what you are doing, and where you are walking.

Nobody ever tripped over something they saw coming. Well, almost nobody. Most of the holes, cords and stair edges on a job are easy to miss when the light is poor. And in the short days of the year we start in the dark and we finish in the dark.

What the rule says

Washington's construction rule sends lighting to the core rules, the ones that cover every employer in the state.

The employer has to provide and maintain adequate lighting for all work activities.

The rule sets minimum light levels, and the company checks them with a light meter. That is their job, not yours. But know this: a dark spot does not get averaged away by a bright one.

There is one more line. Where general lighting is not available, there still has to be enough light for people to see nearby objects that could be hazards, and to see to run emergency controls or other equipment.

Temporary lights

Most of our light on a job is temporary. The construction electrical rule covers that.

Lamps for general lighting are protected from accidental contact and from breaking. That is what the cage on a string light is for. The rule does not say cage. It says protected. But if the cage is gone, the bulb is not protected. Metal-case sockets are grounded.

Temporary lights are not hung by their cords, unless the cord and the light are designed to hang that way.

The cords are the hard usage type, and the connections and insulation are kept in safe condition.

In a wet place, or another place that conducts, like inside a drum, a tank or a vessel, portable electric lighting runs at twelve volts or less. The rule allows a hundred and twenty volt light there only if it is protected by a ground-fault circuit interrupter.

And the rule keeps other outlets off the branch circuits that feed temporary lighting. Those circuits are for the lights. The plain reason is that a tripped saw should not put the stairwell in the dark. That reason is ours, not the rule's words.

Good practice

This part is good practice, not the rule's words.

If a light is out, or a bulb is broken, or a stairwell has gone dark, say so the same day. Do not just learn to walk around it.

A headlamp or a phone light is a backup. It is not the lighting plan.

And when the work moves, the lights move with it. A basement that was bright last week can be dark once the walls go up.

Talk it over

  1. Where on this job is it too dark to see your footing? A stairwell, a basement, a back corner?
  2. When a light goes out, who do we tell, and how fast does it get fixed?

Before you go

Enough light to see the work and the walk. Bulbs guarded. Lights not hung by their cords. And say something about the dark spots.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-155-165 (construction: "For lighting and illumination requirements, see WAC 296-800-210, Lighting"); WAC 296-800-210 (responsibility to provide and maintain adequate lighting); WAC 296-800-21005(1) and Lighting Table (minimum acceptable average lighting level in an area: indoor task 10 foot-candles, outdoor task 5, nontask activities for both indoor and outdoor 3; any one single measurement used to determine the average cannot be less than 5, 2.5 and 1.5; measured at thirty inches above the floor or working surface at the task), (2) (adequate light to see nearby objects that might be potential hazards or to operate emergency controls or other equipment, if general lighting is not available), and its notes (minimal levels for safety purposes only; lighting levels can be measured with a light meter). The note names a voluntary lighting guideline (ANSI/IES RP7-1979); this talk does not open or describe it. Temporary lighting: WAC 296-155-449(1)(b)(ii)(C) (receptacles for uses other than temporary lighting not installed on branch circuits which supply temporary lighting), (E) (lamps for general illumination protected from accidental contact or breakage; metal-case sockets grounded), (F) (hard usage cords with connections and insulation maintained in safe condition; temporary lights not suspended by their electric cords unless designed for it), (G) (portable electric lighting in wet or other conductive locations at 12 volts or less; 120-volt lights if protected by a ground-fault circuit interrupter). Federal: 29 CFR 1926.26 (construction areas where work is in progress lighted with natural or artificial illumination); 1926.56(a) and Table D-3 (minimum foot-candles by area, from 3 for areas such as accessways and excavation up to 30 for first aid stations and offices); 1926.405(a)(2)(ii)(E), (F), (G) (lamps protected, not suspended by cords, 12 volts or GFCI). The Washington and federal tables are built differently (Washington by indoor task, outdoor task and nontask; federal by kind of area), so the numbers do not line up one for one. One other Washington line was seen and not used: WAC 296-155-745 (compressed air work) sets 10 foot-candles on walkways, ladders, stairways and working levels there. "Think of walking through to get somewhere" is our plain example of nontask activity; the rule does not define it in the section read. "That is what the cage on a string light is for," "if the cage is gone, the light is not right," "one bright corner does not make up for a black one" and the tripped-saw reason are plain explanation. The "brewery cord" allowance and splice wording in (F) were left out.