R Safety Hub R Safety Hub Your prescription for a safer workplace

Masonry Walls and the Limited Access Zone

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Today is block and brick. Masonry walls.

A masonry wall is at its best the day it is finished and tied into the building. Until then it is a tall stack of heavy things, held together by something that is still wet. So Washington's construction rule cares a lot about who is standing next to it.

This talk is for the masons, and for everybody else who walks past the wall.

The limited access zone

Whenever a masonry wall is being built, there has to be a limited access zone. That is an area alongside the wall that is clearly marked off to limit who goes in.

Here is what the rule says about it.

It is set up before the wall is started. Not after the third course.

Its size is equal to the height of the wall to be built, plus four feet. The way we picture that, for a wall that will be ten feet tall, the zone reaches fourteen feet out from the wall. The fourteen is our arithmetic. The rule just says height plus four feet.

It runs the whole length of the wall.

It goes on the side of the wall that will not have scaffold on it.

Only the people actively building the wall go in. Nobody else. Not for a shortcut, not to drop off material, not to have a look.

And it stays. The zone stays in place until the wall is supported well enough that it will not tip over or collapse. If the wall is over eight feet tall, the zone stays until the bracing requirements in the next part have been met. And those say the bracing stays until the permanent supporting parts of the structure are in place. So do not take the zone down just because a brace went up. That last line is how we read the rule, the careful way.

Bracing

Every masonry wall over eight feet tall has to be braced well enough to keep it from tipping over or collapsing. The one exception is a wall that is already supported well enough that it will not.

The bracing stays in place until the permanent supporting parts of the structure are in place.

So nobody pulls a brace because it is in the way. If a brace has to move, that is a question for the supervisor, not a favor for the forklift. That last line is plain sense, not the rule's words.

Cutting and chipping

Anyone cutting or chipping wears suitable eye protection. For stone cutters trimming stone or cutting holes, the rule says goggles.

Masonry saws keep their blade guard on. On a table saw, the dust is controlled with an exhaust or with water on the blade, and the operator and anyone nearby wear eye protection. On a hand-held saw, the operator wears eye protection and a respirator.

Silica dust had its own talk, so we will leave the dust there.

The mortar mixer

A mason's mortar mixer has a bar-type grill over the opening. And the guard has an automatic switch. When the guard is not in place, the switch stops the tub from turning and keeps the mixer from starting.

That grill is there because of hands and arms. Leave it on, and do not defeat the switch.

One more thing

The rule also has lines on setting stone with a derrick. Most crews will not see that, so it is not in this talk.

And here is some good practice, not the rule's words. Look at the bracing at the start of the day, and again after a hard wind or after something bumps it.

Talk it over

  1. Where is the limited access zone on this job, and how is it marked?
  2. Who looks at the wall bracing each morning?

Before you go

Zone up before the first block. Wall height plus four feet. Brace anything over eight feet. And the grill stays on the mixer.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-155-675(2) (limited access zone defined: an area alongside a masonry wall under construction, clearly demarcated to limit access by employees); 296-155-697(1) (zone whenever a masonry wall is being constructed), (2) (established prior to the start of construction of the wall), (3) (equal to the height of the wall to be constructed plus 4 feet; entire length of the wall), (4) (on the side that will be unscaffolded), (5) (entry restricted to employees actively engaged in constructing the wall), (6) (stays until the wall is adequately supported to prevent overturning and collapse; over 8 feet, until subsection (7) is met), (7) (walls over 8 feet adequately braced unless adequately supported; bracing stays until permanent supporting elements of the structure are in place), (8) (eye protection for cutting or chipping, per WAC 296-155-215), (9) (masonry saws per WAC 296-155-367(1) through (4)), (16) (mortar mixer bar-type grill and automatic disconnect switch); 296-155-367(1) (semicircular enclosure; method for retaining blade fragments), (2) (safety latch on notched saws), (3) (blade speed per the manufacturer's specifications), (4)(a) (table mounted saws: mechanical exhaust into a covered receptacle or water on the blade; operator and any nearby worker wear eye protection), (4)(b) (portable hand-held saw operators wear eye and respiratory protection, per WAC 296-155-215 and chapter 296-842 WAC), (5) (grounding), (6) (inspection at regular intervals). (13) (stone cutters wear goggles while trimming stone or cutting holes). Left out, and the talk says so: stone setting with derricks (296-155-697(10) to (12), (14), (15)). Federal: 29 CFR 1926.706(a), (b) (limited access zone and bracing; the wording matches the Washington text closely). The eye protection, masonry saw, stone setting and mortar mixer lines were read in the Washington text; they are not in 29 CFR 1926.706, and the other federal concrete and masonry sections were not read today. The ten-foot wall, fourteen-foot example is our arithmetic from subsection (3), and the talk says so aloud; the rule says "equal to the height of the wall to be constructed plus 4 feet" and names no measuring direction. "Do not take the zone down just because a brace went up" is our reading of (6) with (7), the stricter reading: the zone stays until the requirements of (7) are met, and (7) includes the bracing remaining until permanent supporting elements are in place. "Not for a shortcut, not to drop off material, not to have a look," "nobody pulls a brace," "because of hands and arms," "do not defeat the switch" and the bracing look-over are plain sense or good practice, not rule text.