Morning, everybody. Today is pump jacks. If you hang siding, you may know them better than I do. Two poles, two jacks, a platform, and you pump your way up the wall.
It is simple gear. And because it is simple, it gets set up in a hurry. A pump jack will take you up as fast as you can pump. It has no opinion on whether the pole is braced. That part is on us.
The jacks
Washington's scaffold rule says pump jack brackets, braces and accessories are made from metal plates and angles.
Each bracket has two positive gripping mechanisms, to prevent any slipping or failure. Two. If one of them is worn or missing on your jack, that jack is not ready to use.
The poles
Poles get secured to the building with rigid triangular bracing, or something equal to it. At the top. At the bottom. And at other points on the pole as necessary.
Now the part that gets skipped. Sooner or later the jack has to pass a brace on its way up. The rule says you do not just pull that brace and pump past. First you put in an extra brace, about four feet above the one you need to pass. You leave it in. You move the jack past. You put the original brace back. Then the extra one can come out.
Now the one people miss: the mid brace. On a tall pole, braces at the top and bottom are not enough. Three sets of maker's instructions for aluminum pump jack systems that we read say that once the pole goes past twenty-four feet, you need braces in between, no more than sixteen feet apart. Other makers want them closer, every twelve feet, or every ten.
That is the maker's instruction. It is not Washington's rule. The rule only says top, bottom and other points as necessary. So read the maker's instructions for the set you own, and follow them. All three of those sets of instructions say wooden poles may not be used with their systems. If your poles are wood, the rule's bracing still applies in full.
A mid brace is also a brace the jack has to pass. So that is where the extra brace goes in. Some sheets describe passing a brace another way. Washington's rule asks for the extra brace, so it stays, whatever the sheet says.
If you use wood poles, the rule says straight-grained wood, free of shakes, big loose or dead knots, and other defects that could weaken it. If a pole is made of two long pieces, the seam runs parallel to the bracket. And where two-by-fours are spliced to make a pole, every splice gets a mending plate.
The platform and the bench
The platform on a pump jack has to be at least twelve inches wide.
And the work bench is not a platform. The rule says it plainly. Work benches are not used as scaffold platforms. The bench is for material. It is not for boots.
Falls
Washington's rule for scaffolds says that at ten feet or more, each person on the scaffold is protected by guardrails or by a personal fall arrest system.
There is also a gap rule. If the front edge of the platform is more than fourteen inches from the wall you are working on, you need a guardrail along that front edge, or fall arrest.
Before anybody goes up
Scaffolds are put up, moved, changed and taken down under a competent person, by trained and experienced people the competent person picks.
A competent person looks the scaffold over before each shift, and again after anything happens that could have affected it. A truck bumping a pole counts.
And it gets loaded the way the maker's instructions say, or to a qualified person's design, and never past its rated or intended load, whichever is less. The maker's instructions also tell you how high your system can go. Read them for the set you actually have, because different systems have different answers.
Talk it over
- Who on this crew checks the pole bracing, and the mid brace on a tall pole, before the first person goes up?
- When we pass a brace, what do we actually do? Does it match what the rule says?
Before you go
Braced top and bottom, and in between when your maker's sheet says the pole is tall enough. Read it for the spacing. An extra brace in before you pass one. And nobody stands on the bench.