Scaffolds Near Power Lines

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. Before anybody sets up today, look up. Look at the wire coming from the pole to the house, and any lines running along the street or the back of the lot.

Power lines don't hum a warning. And a scaffold frame, an aluminum plank or a length of metal flashing doesn't care whether you meant to touch the line.

What the rule says

A scaffold has to stay a set distance from exposed, energized power lines. In Washington that counts when it's going up, being changed, being moved, and coming down. The federal rule adds while it's being used. And it counts for anything conductive you're handling on it, too. Metal trim, coil stock, a metal pole, a long tool.

Here are the distances in the Washington rule.

The wire to the house, under three hundred volts, if it's insulated: at least three feet.

Under three hundred volts, not insulated: at least ten feet.

Three hundred volts up to fifty thousand volts: at least ten feet.

Over fifty thousand volts, it's ten feet plus a little under half an inch for every extra thousand volts.

Here's the catch. From the ground, most of us can't tell the voltage, and we can't tell if the covering on a wire is really insulation. Good practice, not rule text: if you don't know what a line is, treat it as live and uninsulated. Stay at least ten feet back, you and everything you're carrying, and farther if it might be a high-voltage line. Then ask someone who knows the voltage.

When the job needs you closer

Sometimes the wall you're working on is right under the service drop. The rule allows a scaffold and material to be closer only if all three of these happen. The work really needs it. The utility company or whoever runs the lines has been told. And they've done at least one thing: shut the lines off, moved them far enough to meet the distance, or put protective covers on them.

So the crew doesn't decide to squeeze in closer. Good practice: that call goes to the supervisor, and the supervisor calls the utility.

Moving and carrying

Rolling a scaffold or walking a pump jack pole past a line is when people get surprised. Good practice: look up before you move anything tall. When you raise a long piece of metal up the scaffold, keep it low and pointed away from the lines.

If a line comes down or gets touched

Good practice, not rule text. If a line comes down, or anything touches one, stop and stay back at least thirty-five feet.

Keep everyone else back too. The ground around it can be live.

Call nine one one, then the utility. Nobody goes near until the utility says the power is off.

Don't grab anyone touching a line or anything it touches. You become the next victim.

On a machine that's touched a line? Stay put unless there's fire. If you must leave, jump clear, land with feet together, and shuffle away.

Once the power is confirmed off: check breathing and pulse. No pulse, start CPR. Cool water on burns. Don't move them if the neck or back may be hurt.

Anyone who got a shock gets checked by medical, even if they feel fine. The heart can be hurt inside.

Talk it over

  1. Where are the lines on this job, and how close is our scaffold to them?
  2. Who calls the utility if we need to work closer?

Before you go

Look up before you set up. Know the distance. Count what you carry. And if it's close, stop and get the utility involved.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-874-20046 and Table 2 (scaffolds erected, moved, altered or dismantled so that they and any conductive material handled on them are kept at least the table distance from exposed energized power lines: under 300 volts insulated 3 feet; under 300 volts uninsulated 10 feet; 300 volts to 50 kV 10 feet; over 50 kV 10 feet plus 0.4 inch per kV over 50; alternative of 2 times the insulator length, never under 10 feet; exemption only if less clearance is necessary, the utility or system operator is notified, and the utility has de-energized, relocated or covered the lines). Federal: 29 CFR 1926.451(f)(6) and exception (same distances for insulated lines; uninsulated lines under 50 kV 10 feet; scaffolds may not be erected, used, dismantled, altered or moved closer). Note: the Washington sentence names erecting, moving, altering and dismantling; the federal sentence also names "used," and the talk follows the federal wording for "while it's being used." Examples (service drop, coil stock, flashing, pump jack pole), "treat an unknown line as live and uninsulated, ten feet and farther if it might be high voltage," "the supervisor calls the utility," "keep it low and pointed away," and the downed-line line are good practice or plain explanation, not rule text.