R Safety Hub R Safety Hub Your prescription for a safer workplace

Steep Roofs — Roof Brackets, Crawling Boards and the Edge (Part 2 of 2)

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. This is part two about steep roofs, anything steeper than four in twelve. Part one was the rule: on a steep roof, from four feet up, you're on restraint, fall arrest or positioning, every time. Today is the things that help you stand, and the edge.

Roof brackets are not fall protection

The rule says it plainly: roof brackets aren't a fall protection system. They are a place to stand and a place to stack. Good ones save your legs. They do not save your life.

What the rule asks of them is simple. The brackets fit the pitch of the roof. They are nailed in place, not just set on their pointed teeth. If nailing truly is not practical, rope supports are used: first grade manila rope, at least three-quarter inch, or rope that is just as good. A separate rule, the one for roof bracket scaffolds, adds that the brackets give the plank a level place to sit.

So before you step onto a bracket plank, look. Is each bracket nailed? Is the plank sitting level and solid? Somebody always says, "That bracket's been fine all morning." Brackets don't get tired. Nails pull out.

Crawling boards and chicken ladders

Same story. The rule says crawling boards and chicken ladders are not fall protection either.

When a crawling board is used for roof construction, repair or maintenance, it runs from the ridge all the way to the eaves. It is secured to the roof with ridge hooks or something just as good. It is at least ten inches wide and one inch thick. The cleats are one by one and a half inches, as long as the board is wide, evenly spaced no more than two feet apart, and nailed through and bent over underneath.

A board that stops halfway down the roof is a ramp to nowhere.

Material and equipment near the edge

No material stored within six feet of the roof edge unless there is a guardrail at the edge. If anyone could be working or walking below, that guardrail gets a toeboard. A bundle sliding off is a problem for the person on the ground.

Machines are used or stored only where people are protected by a fall arrest or fall restraint system. And the hoist is never your anchor, not for arrest and not for restraint.

Where materials are hoisted up to the roof edge and guardrails are used, there's at least four feet of guardrail on each side of the hoisting spot. When nobody is hoisting, a chain or gate goes across it. And where guardrails are used at the outlet of the pipe that carries bitumen, they run four feet on each side of it too.

Talk it over

  1. Pick one bracket or board on this job. Is it nailed, level and fitted to the pitch?
  2. Where is material sitting near the edge, and what is between it and the drop?

Before you go

Brackets and boards help you stand. Your harness and your line keep you on the roof.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-880-40070 (roof brackets are not a fall protection system; fit the pitch; nailed as well as the pointed projections, or first grade manila rope at least three-quarter inch, or equivalent); 296-874-40036 (roof bracket scaffolds, a different chapter: fit the pitch, (2) level support for the platform, anchored by nails; the rope is in the Note); 296-880-40075 (crawling boards and chicken ladders are not fall protection; ten inches by one inch, cleats one by one and a half inches, equal in length to the board's width, equal intervals not over 24 inches, nails driven through and clinched; ridge to eaves when used in connection with roof construction, repair, or maintenance (1)(c); secured to the roof with ridge hooks or equivalent means (2)); 296-880-40080(1), (2), (3), (4), (5), (6) (four feet of guardrail each side of a hoisting opening, chain or gate when not hoisting, four feet each side of a bitumen pipe outlet when guardrails are used, mechanical equipment only where arrest or restraint protects, hoist not an anchor, material six feet from the edge unless guardrails, toeboard if employees could be working or passing below); 296-880-20005(6) (steep roof: restraint, arrest or positioning). "Nails pull out", "look before you step" and "a board that stops halfway is a ramp to nowhere" are good practice or humour, not rule text; the opening recap of Part 1 summarizes 296-880-20005(6).