R Safety Hub R Safety Hub Your prescription for a safer workplace

Table Saws and Fixed Saws (Part 2 of 2)

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. This is part two about saws. Part one was the circular saw. Today is the table saw and the fixed saws.

The table saw

On a hand-fed table saw, there is a hood guard over the blade. When you are cutting, the hood covers the part of the blade above the wood. When you are not cutting, it covers the blade. If your hood is the kind you set by hand, it sits close to the wood. The gap is no more than a quarter inch within an inch and a half of the blade, and no more than three-eighths of an inch farther out.

Some cuts, like unusual shapes, can't be made with the hood on. For those, the rule wants a jig or fixture that is just as safe. And the minute you finish, the guard goes back on.

For ripping, the saw has a spreader behind the blade, so the wood can't pinch the blade and kick back. It also has anti-kickback devices that push back against the board and hold it. The spreader can come off for grooving, dado or rabbet cuts. When that cut is done, it goes right back on.

When the piece is short or narrow and your hand could get near the blade, you use a push stick. Fingers are not push sticks. They don't grow back, either.

Somebody always says, "It's one cut, I'll just run it without the guard." That one cut is the one we're talking about.

Miter saws and radial arm saws

A miter saw follows the same guard rule as a radial arm saw: an upper hood over the upper blade, and a lower guard that adjusts itself and stays against the work for the ninety-degree blade positions. The same rule brings the warning label about jammed guards. On both saws, the guards stay on.

A radial arm saw carries a warning label to shut off the power before clearing a jammed lower guard. On a manually operated one, another label says to bring the carriage all the way back after each crosscut. Which way the blade turns is marked on the hood, and a danger label says not to feed material from the end where the teeth come out. When you rip on a radial arm saw, it has a spreader and anti-kickback devices, and you feed against the way the blade turns. Never from that marked end.

On a stationary radial arm saw, the switch is at the front, recessed or covered so nobody bumps it on. The floor in front of it is kept firm, level and clear. And on any power saw, the rule says to use a push stick or something similar for short material.

A fixed power tool, one that is set in place, has a disconnect switch that can be locked or tagged off. Having it is the rule. Using it before you change a blade or clear a jam is our own good practice. For a saw you carry around, unplugging it or pulling the battery is good practice too.

Talk it over

  1. Where is the push stick for our table saw right now?
  2. Is the spreader on, and where is the disconnect for the fixed saw?

Before you go

Hood on. Spreader on for ripping. Push stick, not fingers. Good practice: lock off a fixed saw before you clear a jam.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-155-350(4)(e) (disconnect switch on fixed tools); 296-155-370(3)(a) to (h) (table saw hood guard, hand-set hood gap one-quarter inch within one and a half inches of the blade and three-eighths inch beyond; jig or fixture where a hood cannot be used, guard replaced immediately after; push stick on short or narrow stock; spreader, not required for grooving, dadoing or rabbeting and replaced immediately after; antikickback devices), (4)(a), (b), (c), (e), (f) (radial saw guards and jammed-guard label; spreader; antikickback devices; return-carriage label on manually operated saws (4)(e); feed against the direction of blade rotation; direction of rotation conspicuously marked on the hoods, which is a marking, not a warning label; do-not-feed-from-this-end danger label), (6) (stationary radial arm saws: switch at the front, recessed or hooded; firm level area free of stumbling hazards; (6)(b) push stick or similar device for pushing short material through power saws, which covers power saws generally), (7) (circular power miter saws: the (4)(a) guarding applies; lower guard stays in contact with the stock for the 90 degree blade positions, 0 degree bevel). Federal: 29 CFR 1926.304(a), (g), (h), (i). Pointer, not quoted in detail: WAC 296-155-370(5) and 29 CFR 1926.304(f) point to an ANSI woodworking code; this talk does not describe it. "Using the disconnect before a blade change or clearing a jam" is good practice; having it on fixed tools is the rule. The firm-floor rule is for radial arm saws only (370(6)(a)).