Morning, everybody. It's getting cold. Which means the heaters are coming out. Propane heaters, kerosene heaters, the big torpedo heaters, the ones somebody's cousin swears are the best.
Heaters are great. Nobody does good work with frozen fingers. But a heater burns fuel inside a space where we're breathing. So today is two things: fire, and the gas you can't see.
The gas you can't see
Anything that burns fuel makes carbon monoxide. Heaters, generators, gas saws, trucks, compressors with engines.
The CDC says carbon monoxide has no color and no smell. You won't know it's there. The most common signs are headache, dizziness, weakness, upset stomach and throwing up. Breathe enough of it and you can pass out, or die.
Here's the tricky part. Those first signs feel like a cold, or a long day, or a bad breakfast. So, good practice: if you start feeling that way in a closed-up space with a heater or an engine running, and you feel better when you step outside, take it seriously. Get to fresh air. Tell somebody. And if someone passes out, call nine-one-one. When in doubt, have it checked out.
For the person reading: this is general information, not medical advice.
Fresh air is the rule
Washington's rule for temporary heaters says there has to be enough fresh air to keep workers healthy and safe. If natural air isn't enough, the company has to bring in mechanical ventilation. Fans, ducts, whatever does the job.
When we wrap a building in plastic to keep the heat in, we're also keeping the bad air in. Crack it open somewhere. Let it breathe.
And generators? The CDC's advice for homes is never inside, even with the doors and windows open, and outside more than twenty feet from doors, windows and vents. A building we're closing in is not so different. Good practice: generators outside, pointed away from openings.
A CO detector on the job is good practice, not a rule. Worth asking about.
Fire
Heaters are also fire starters. The rule says heaters near tarps, canvas or plastic sheeting stay at least ten feet away from them. And those coverings get tied down, so wind doesn't blow them into the heater or knock the heater over.
Heaters have clearance distances to anything that burns. The maker's label says what they are. For some radiant heaters, the rule's table says three feet. Keep the space clear. No drying your gloves on the front of it. I know. I know. But no.
A heater not made to sit on wood goes on concrete or insulating material that sticks out two feet all around. Set it level. And oil heaters have to shut off the fuel if the flame goes out.
Propane
The rule says a propane heater stays at least six feet from any propane tank, unless it's the kind built to sit on the tank. Don't hang the heater off the hose or the regulator. And propane cylinders don't get stored inside the building. Overnight, they go outside.
Talk it over
- Where are we running heaters or engines in closed-up spaces right now, and how is fresh air getting in?
- Is anything that can burn, like plastic, tarps or rags, closer than it should be to a heater on this job?
Before you go
Heaters need fresh air. Ten feet from tarps. Propane tanks six feet away and outside overnight. Headache in a closed space? Get outside and tell somebody.