R Safety Hub R Safety Hub Your prescription for a safer workplace

Window and Wall Openings

Lines in italics are for the reader, not the crew. How to read a talk

Printable version with sign-in sheet (PDF)

Read this out loud

Morning, everybody. We've talked about floor holes and roof edges. Today is about the holes in the walls. Window openings before the window goes in. A door framed on the second floor that opens onto a deck that isn't built yet. A gap left for a hoist or a chute.

These don't feel like edges. You're standing inside, on a solid floor, with a wall around you. Then you lean out to hand something down, or back up to look at your work.

What counts as an opening

In the rule, an opening is a gap in a wall or partition at least thirty inches high and eighteen inches wide, that somebody could fall through to a lower level. That takes in a lot of window openings, door openings, and rough gaps.

When it needs protection

Washington's rule says it needs protection when both of these are true. One: the outside bottom edge is four feet or more above the level below. Two: the inside bottom edge, the sill, is less than thirty-nine inches above the floor you're standing on.

So a low window on the second floor? Yes. A door opening to nowhere, four feet or more up? Yes. A high window with a sill at chest height is not covered by this line. But stand on a bucket or a stepladder in front of it, and that sill just got a lot lower. Our advice: treat it like a low one.

The rule says the protection is one of these: a guardrail, a safety net, a personal fall arrest system, or a fall restraint system. On most of our jobs that means a guardrail across the opening, or a harness tied off when you have to work right at it.

And the rule covers anybody working on, at, above or near that opening. Not just the person framing it.

Keep it in place

A guardrail across an opening is not a door. Don't take it down to pass material through and leave it down. If the job needs it out, check with your supervisor first. Anybody working at the open spot while it's out still needs fall protection, like a harness tied off. Put it back before you walk away.

A two-by-four nailed across a door opening with two nails is not a guardrail. A real guardrail has posts, a top rail between thirty-nine and forty-five inches high, and a midrail, and the top rail has to hold two hundred pounds pushed out or down. If what you see looks like a suggestion, say so.

Good practice: plan where material comes in, so nobody has to lean out of an open window to grab a bundle.

Talk it over

  1. Walk the floors in your head. Where's an opening on this job right now with nothing across it?
  2. When did you last pass material through an opening, and was the rail back up when you left?

Before you go

If the sill is low and the drop is four feet or more, it gets a rail, a net, or you get tied off. And the rail goes back up.

Short on time, or no one to lead it? Doc and Red can run this talk for you in the R Safety Hub app.

Get started

Reference (not read aloud). Washington: WAC 296-880-095(38) (opening: gap 30 inches or more high and 18 inches or more wide in a wall or partition, through which employees can fall to a lower level); 296-880-20005(4) (employees working on, at, above or near openings, including those with chutes, where the outside bottom edge is four feet or more above a lower level and the inside bottom edge is less than 39 inches above the working surface: guardrail system, safety net system, personal fall arrest system or personal fall restraint system); 296-880-40005 (guardrail specifications: top rail, intermediate rail, strength). Federal: 29 CFR 1926.501(b)(14) (wall openings at six feet; guardrail, safety net or personal fall arrest); 1926.500(b) (opening definition, same size). Differences seen: Washington triggers at four feet, federal at six; Washington adds fall restraint. "Stand on a bucket and the sill gets lower; treat it like a low one" is our safe reading (the rule measures the sill from the working surface; compare 296-880-20005(1)(a)(ii) for guardrails at edges). "A rail across an opening is not a door," "check with your supervisor before taking it out," "two nails is not a guardrail" and planning material routes are good practice or plain reading of the guardrail specifications, not rule text. Guardrail numbers: 296-880-40005(1), (2)(e), (f) (top rail 39 to 45 inches, intermediate rail, posts, 200 pounds within two inches of the top edge outward or downward). "Anybody at the open spot while the rail is out still needs fall protection" follows 20005(4) itself (the employee at the opening is protected by one of the four systems); the attendant rule in 20005(1)(a)(iii) is written for edges and is not claimed here.